Mains Wiring - WARNING: Electricity can KILL
Before connecting the control panel ALWAYS disconnect the supply at the consumer
unit. A 230V a.c supply should be taken directly from the consumer unit. In order to
comply with the relevant current wiring regulations this should be via a 3 Amp fused
spur with disconnection facility. This must be carried out by a suitably qualified electri-
cian. If you are in any doubt please contact your local electricity company for advice.
This control panel MUST be Earthed.
Page
5
GT490X Engineer’s Reference Guide
Consumer Unit
3A Unswitched
Fused Spur
Control Panel Mains
Terminal Block
Mains
Connection Colours
Live
= Brown (Red)
Neutral = Blue (Black)
Earth
= Copper
Yellow/Green sleeving should be
used for Copper Earth Conductor