beautypg.com

HEIDENHAIN iTNC 530 (340 49x-03) User Manual

Page 95

background image

HEIDENHAIN iTNC 530

95

2.6 Dynamic Collision Monit

o

ri

ng (Sof

tw

ar

e Option)

Warning zone

Two objects monitored for collision are within 6 to 8 mm of each other
The error message displayed (the machine manufacturer determines
the exact text) always starts with this text string: |<->|.

8

Acknowledge the error message with the CE key.

8

Manually traverse the axes out of the danger zone. Pay attention to
the direction of traverse.

8

If applicable, remove the cause of the collision message.

Error zone

Two objects monitored for collision are less than 2 mm from each
other The error message displayed (the machine manufacturer
determines the exact text) always starts with this text string: |<>|. In
this state you can only traverse the axes after deactivating collision
monitoring.

8

Shift the soft-key row if necessary.

8

Select the menu for deactivating the collision

monitoring.

8

Select the Manual Operation menu item.

8

To deactivate collision monitoring, press the ENT key,

and the symbol for collision monitoring in the
operating mode display starts to blink.

8

Acknowledge the collision error message with the CE key.

8

Manually traverse the axes out of the danger zone. Pay attention to
the direction of traverse.

8

If applicable, remove the cause of the collision message.

8

To reactivate the collision monitor: Press the ENT key.

Danger of collision!

Remember to move the axes in the correct direction when
backing off from the workpiece. In this condition the TNC
does not monitor for collisions.

If you have deactivated the collision monitoring, the
symbol for collision monitoring flashes (see following
table).

Function

Symbol

Symbol that appears in the operating mode bar
when the collision monitoring is not active.