beautypg.com

1 1 pr eassigned q p ar amet ers – HEIDENHAIN iTNC 530 (340 49x-03) User Manual

Page 617

background image

HEIDENHAIN iTNC 530

617

1

1

.1

1 Pr

eassigned Q

P

ar

amet

ers

Workpiece status

Parameter value

Good

Q180

Re-work

Q181

Scrap

Q182

Measured deviation with Cycle 440

Parameter value

X axis

Q185

Y axis

Q186

Z axis

Q187

Tool measurement with the BLUM laser.

Parameter value

Reserved.

Q190

Reserved.

Q191

Reserved.

Q192

Reserved.

Q193

Reserved for internal use

Parameter value

Markers for cycles (point patterns)

Q197

Number of the last active measuring cycle

Q198

Status during tool measurement with TT

Parameter value

Tool within tolerance

Q199 =0.0

Tool is worn (LTOL/RTOL exceeded)

Q199 =1.0

Tool is broken (LBREAK/RBREAK exceeded)

Q199 =2.0