13.19 External Access

Function

The soft key SERVICE can be used to grant or restrict access through
the LSV-2 interface.

With an entry in the configuration file TNC.SYS you can protect a
directory and its subdirectories with a password. The password is
requested when data from this directory is accessed from the LSV-2
interface. Enter the path and password for external access in the
configuration file TNC.SYS.

Example of TNC.SYS

Permitting/Restricting external access

8

Select any machine mode of operation.

8

Press the MOD key to select the MOD function.

8

Permit a connection to the TNC: Set the EXTERNAL

ACCESS soft key to ON. The TNC will then permit
data access through the LSV-2 interface. The
password is requested when a directory that was
entered in the configuration file TNC.SYS is accessed.

8

Block connections to the TNC: Set the EXTERNAL

ACCESS soft key to OFF. The TNC will then block
access through the LSV-2 interface.

The machine tool builder can configure teleservice
settings with the LSV-2 interface. The machine tool
manual provides further information.

The TNC.SYS file must be stored in the root directory
TNC:\.

If you only supply one entry for the password, then the
entire drive TNC:\ is protected.

You should use the updated versions of the HEIDENHAIN
software TNCremo or TNCremoNT to transfer the data.

Entries in TNC.SYS

Meaning

REMOTE.TNCPASSWORD=

Password for LSV-2 access

REMOTE.TNCPRIVATEPATH=

Path to be protected

REMOTE.TNCPASSWORD=KR1402

REMOTE.TNCPRIVATEPATH=TNC:\RK