Activating manual tilting, 5 tilting the w o rk ing plane – HEIDENHAIN iTNC 530 (340 420) ISO programming User Manual
Page 55

HEIDENHAIN iTNC 530
55
2.5 Tilting the W
o
rk
ing Plane
Activating manual tilting
To select manual tilting, press the 3-D ROT soft key.
You can now select the desired menu items with the
arrow keys.
Enter the tilt angle.
To set the desired operating mode in menu option “Tilt working plane”
to Active, select the menu option and switch with the ENT key.
To conclude entry, press the END key.
To reset the tilting function, set the desired operating modes in the
menu “Tilt working plane” to Inactive.
If the tilted working plane function is active and the TNC moves the
machine axes in accordance with the tilted axes, the status display
shows the symbol
.
If you activate the “Tilt working plane” function for the Program Run
operating mode, the tilt angle entered in the menu becomes active in
the first block of the part program. If you are using G80 WORKING PLANE
in the part program, the angular values defined in the cycle (starting at
the cycle definition) are effective. Angle values entered in the menu
will be overwritten.