beautypg.com

Delete modal program information: m142, Delete basic rotation: m143 – HEIDENHAIN iTNC 530 (340 420) ISO programming User Manual

Page 201

background image

HEIDENHAIN iTNC 530

201

7.

4 Miscellaneous F

unctions f

o

r Cont

our

ing Beha

vior

Delete modal program information: M142

Standard behavior

The TNC resets modal program information in the following situations:

n

Select a new program.

n

Execute a miscellaneous function M02, M30, or an N999999 %...
block (depending on MP7300).

n

Defining cycles for basic behavior with a new value

Behavior with M142

All modal program information except for basic rotation, 3-D rotation
and Q parameters are reset.

Effect

M142 is effective only in the block in which it is programmed.

M142 becomes effective at the start of the block.

Delete basic rotation: M143

Standard behavior

The basic rotation remains in effect until it is reset or is overwritten
with a new value.

Behavior with M143

The TNC erases a programmed basic rotation from the NC program.

Effect

M143 is effective only in the block in which it is programmed.

M143 becomes effective at the start of the block.