Configuration process, Vsd pc ip settings, Connecting to the network – Grass Valley Jupiter v.1.1.0 User Manual
Page 85: Vsd application settings, E the configuration process, Operational (see configuration process
JUPITER AccuSwitch Soft Panels and Visual Status Display Instruction Manual
75
Configuration Process
Configuration Process
VSD PC IP Settings
The PC on which the Jupiter Visual Status Display (VSD) application is
installed, must have network settings that allow communication with the
Jupiter AccuSwitch Controller. Consult with your Network administrator
for this information.
Connecting to the Network
The Soft panel and VSD connect to the Network using one of two ports.
These ports are:
•
Port 420
•
A port number that is the Device ID added to 50000. For example, if the
Device ID is 21, the port number would be 50021.
Note
If the GUI panel is behind a firewall, the ports listed above will need to be
opened for the Soft panel and VSD to communicate with the AccuSwitch
Control module.
VSD Application Settings
During the following steps, you will need to know the IP address of the
primary AccuSwitch Controller (and the secondary, if it is installed) that
will be associated with the VSD. Use the Jupiter File Server JNS Control
Center application “Board Info” tab to determine the AccuSwitch Con-
troller IP address (the Control Center application is described in the Jupiter
CM-4000 Installation and Operating manual).
1.
Launch the VSD application. The main VSD screen (shown in
) will open and the Router Connection Settings dialog will
then be displayed.