Configuring the maximum number of concurrent

users

You can limit the number of users that can perform operation in system view simultaneously. When

multiple users configure a setting in system view, only the last configuration applies.
When the number of concurrent users reaches the upper limit, other users cannot enter system view.
To configure the maximum number of users that can enter system view simultaneously:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Configure the maximum
number of concurrent users.

configure-user count number

Optional.
By default, up to two users are
allowed to perform operations in

system view at the same time.

Configuring the exception handling method

The firewall supports the following software exception handling methods:

reboot—The firewall automatically reboots to recover from the error condition.

maintain—The firewall stays in the error condition so you can collect complete data, including error
messages, for diagnosis. In this approach, you must manually reboot the firewall.

When multiple users configure a setting in system view, only the last configuration applies.
When the maximum number of concurrent users is reached, other users cannot enter system view.
To configure the exception handling method:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Configure the exception

handling method.

system-failure { maintain | reboot }

Optional.
By default, the system reboots
when an exception occurs.

Rebooting the firewall

This section describes how to reboot the firewall.