H3C Technologies H3C SecPath F1000-E User Manual
Page 62

54
[FW card-ui-aux0]
# Log in to the firewall module.
Connected to OAP!
2.
Configure the clock synchronization timer and the monitoring timer on the network device:
# Enable ACSEI server.
[Switch] acsei server enable
# Enter ACSEI server view.
[Switch] acsei server
# Set the clock synchronization timer to 10 minutes.
[Switch-acsei server] acsei timer clock-sync 10
# Set the monitoring timer to 10 seconds.
[Switch-acsei server] acsei timer monitor 10
3.
Enable ACSEI client on the Ten-GigabitEthernet 0/0 interface.
[FW card] interface Ten-GigabitEthernet0/0
[FW card] acsei-client enable
4.
Verifying the configuration:
# Restart the firewall module on the network device.
This command will recover the OAP from shutdown or other failed state.
Warning: This command may lose the data on the hard disk if the OAP is not being
shut down! Continue? [Y/N]:y
Reboot OAP by command.
The output shows that you can restart the firewall module on the network device.
# Display the ACSEI server configuration information on the network device.
#
acsei server
acsei timer clock-sync 10
acsei timer monitor 10
#
return
[Switch]
The output shows that the clock synchronization timer and monitoring timer are 10 minutes and 10
seconds, respectively.
- H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS