Alm led is red, Him/mim failures, Configuration system problems – H3C Technologies H3C SR6600 User Manual
Page 95: No terminal display
85
ALM LED is red
When the router is running, the ALM LED on the fan tray panel might turn red, and the following
information might appear on the configuration terminal:
%Jul 5 14:59:03:878 2010 H3C DRVMSG/3/FanPlugIn:Fan 1 Plug In.
%Jul 5 14:59:03:879 2010 H3C DRVMSG/3/FanErr:Fan 1 Error.
#Jul 5 14:59:03:998 2010 H3C DEV/1/FAN STATE CHANGES TO FAILURE:
Trap 1.3.6.1.4.1.2011.2.23.1.12.1.6
%Jul 5 14:59:03:998 2010 H3C DEV/4/FAN FAILED:
Fan 1 failed.
The output shows that fan 1 is faulty.
To solve the problem, check whether any foreign object has entered the fan tray.
If the cause cannot be located in the steps above and the problem persists, contact your local sales
agent.
HIM/MIM failures
When a HIM/MIM is plugged while the router is running, the following information might appear on the
configuration terminal:
%Apr 26 15:36:09:404 2010 H3C DRVICOUT/1/DrvIcOutStr:Slot=5;(Src Slot[5])
Slot 5/2 Plug In Failed!
The output indicates that the HIM/MIM is faulty or the router cannot recognize the HIM/MIM.
To troubleshoot the HIM/MIM failure:
1.
Verify that the HIM/MIM is firmly seated.
2.
Verify that the HIM is correctly plugged into a FIP-210 module. A FIP-110 module does not support
a HIM.
3.
Verify that the interface module connector pins of the FIP module are bent.
4.
If the cause cannot be located in the steps above and the problem persists, contact your local sales
agent.
Configuration system problems
If the configuration environment setup is correct, the configuration terminal displays boot information
when the router is powered on. If the setup is incorrect, the configuration terminal displays nothing or
garbled text.
No terminal display
If the configuration terminal displays nothing when the router is powered on, follow these steps to
troubleshoot the failure:
1.
Verify the following items.
{
The power supply system works correctly.