Table 67 – H3C Technologies H3C SR6600 User Manual
Page 147
137
Table 67 MCP-X1 LED description
LED Status
Description
(yellow/green)
GE0 through
GE3
Off
The corresponding interface is not connected.
Steady green
A 1000 Mbps link is present.
Flashing green
Data is being received or transmitted at a rate of
1000 Mbps.
Steady yellow
A 10/100 Mbps link is present.
Flashing yellow
Data is being received or transmitted at a rate of
10/100 Mbps.
(yellow/green)
CF card LED
Off
No CF card is present or the CF card is not
recognizable.
Steady green
A CF card is in position and has been detected.
Flashing green
The system is accessing the CF card. In this state,
do not remove the CF card.
Steady yellow
A CF card not provided by H3C.
(green)
Run LED
Off
No power input is available, or the MCP-X1 has
failed.
Slow flashing (1
Hz)
The MCP-X1 is operating correctly.
Fast flashing (8
Hz)
The application software is being loaded (in this
case, never power off the device or hot-swap the
MCP-X1; otherwise the MCP-X1 might be
damaged).
(green)
Active LED
Off
The MCP-X1 is in standby state.
Steady on
The MCP-X1 is in active state.
(red)
Power
management
alarm LED
Off
The system power module is normal.
Steady on
The system power is insufficient.
(red)
Alarm LED
Off
The system is operating correctly and there is no
alarm.
Steady on
A fault has occurred to the system or the available
power is insufficient. In this state, check the system
log immediately.
LINK LED
Off
The corresponding interface is not connected.
Steady green
A 1000 Mbps link is present.
Steady yellow
A 10/100 Mbps link is present.
ACT LED
Off
No data is being received or transmitted.
Flashing yellow
Data is being received or transmitted.