Precautions – H3C Technologies H3C SR6600 User Manual
Page 41
31
performance indexes of the surge protector as lightning protection, bandwidth, transmission loss, and
port type.
The router supports the following types of surge protectors:
•
Surge protector/Maximum discharge current 2.5KA/protection voltage 25V--SMB-75J/
SMB-75J-1W-10Mbps
•
Surge protector/Maximum discharge current 2.5KA/protection voltage 25V-BNC-75K/
BNC-75K-10Mbps
•
Surge protector (U port)/Maximum discharge current 3KA/common-mode 400V/differential
mode 170V-RJ11
To install a surge protector:
1.
Use a double-faced adhesive tape to stick the surge protector onto the router chassis, and make
sure it is as close to the grounding screw of the router as possible.
2.
Measure the distance between the protector and the grounding screw of the router, cut the ground
wire of the protector as appropriate, and securely tighten the ground wire to the grounding screw
of the router.
3.
Use the multimeter to measure whether the ground wire of the protector contacts well with the
grounding screw of chassis.
4.
Insert the outdoor network cable into the protector's IN end, and the cable connected to the router
into the OUT end, and look at the indicators on the surge protector to verify that the connection is
correct.
5.
Use nylon ties to bundle the cables neatly.
Figure 34 Installing a surge protector
Precautions
The performance of the surge protector might be affected in the following cases: