Table 16 Output description
Field Description
Fan 1
Number of the fan
State
The fan state:
•
Normal—The fan is operating correctly.
•
Absent—The fan is not in position.
•
Fault—The fan fails.
Displaying the operational status of power supplies
Use the display power command to display the operational status of power supplies.
Power 1 State: Absent
Power 2 State: Normal
Table 17 Output description
Field Description
Power 1
Number of the power supply
State
The power supply state:
•
Normal—The power supply is operating correctly.
•
Absent—The power supply is not in position.
•
Fault—The power supply fails.
Displaying the alarming thresholds of a module
When the router is operating, too high a temperature and too low a temperature of a module affect the
normal operation of the router. When the temperature of a module exceeds 80°C (176°F) or drops below
0°C (32°F), the system sends traps to prompt you to solve the problem.
To display the alarming thresholds of a module:
Step Command…
Remarks
1.
Enter system view.
system-view
N/A
2.
Display the temperature
information of your router.
display environment
Optional
Available in any view