Troubleshooting, Mpu failures, Run led is off – H3C Technologies H3C SR6600 User Manual

Page 92: Run led fast flashes, Alm led is steady on or flashes

background image

82

Troubleshooting

IMPORTANT:

The barcode stuck on the router chassis contains production and servicing information. Before you return
a faulty router for serving, provide the barcode information of the router to your local sales agent.

MPU failures

RUN LED is off

When the RUN LED of the MPU is off, it indicates that the MPU is powered off or faulty. For more

information about the RUN LED, see "

Appendix C LEDs

."

To troubleshoot the MPU failure:

1.

Check whether the MPU is plugged in a right slot.

{

An RPE-X1 MPU must be plugged in slot 0 or slot 1.

{

An RSE-X1 MPU must be plugged in slot 1 or slot 2.

{

An MCP-X1/X2 must be plugged in slot 1 or slot 2.

2.

Check whether the router is powered on normally. A green POWER LED indicates that the router
is powered on normally.

3.

If the cause cannot be located in the steps above and the problem persists, contact your local sales
agent.

RUN LED fast flashes

Five minutes after the router is powered on or the MPU is plugged into the router, if the RUN LED of the

MPU still fast flashes at 8 Hz, it indicates that the MPU application program fails to start or the MPU is

faulty.
To troubleshoot the MPU failure:

1.

Verify that the terminal display is correct.

2.

Verify that the application program file properties are correct in the BootWare menu.

3.

If the cause cannot be located in the steps above and the problem persists, contact your local sales
agent.

ALM LED is steady on or flashes

If the ALM LED of the MPU is steady on or flashes, it indicates that the router is faulty.
For example, the ALM LED is on when the system is over-temperature. In this case, the system displays the

following output:

%Jun 25 14:38:45:444 2010 H3C DRVMSG/3/TempCritical:

CPU temperature critical in Slot 3, index is 1.