Fip-240 combo interface specifications, Service aggregation platform modules, Sap-48gbe – H3C Technologies H3C SR6600 User Manual
Page 132
122
NOTE:
•
For a combo interface, the default operating port is the copper port. You can use either the copper port
or the fiber port. To switch between the copper and fiber ports, use the combo enable { copper | fiber }
command in interface view. For more information about the combo enable { copper | fiber } command,
see
H3C SR6600/SR6600-X Routers Interface Command Reference.
•
Use transceiver modules for the fiber ports provided by H3C only. The router might be incompatible with
transceiver modules from other manufacturers. The system generates an alarm when a transceiver
module from another manufacturer is installed.
FIP-240 combo interface specifications
Specification of combo interfaces on the FIP-240 and the FIP-110 are the same. For more information,
see
Transceiver modules available for the FIP-240 fiber ports and the FIP-110 fiber ports are the same. For
more information about transceiver modules, see
.
Maximum interface modules provided by FIP-240 in full configuration
Interface
module
One RPE-X1
Two RPE-X1s
One RSE-X1
Two RSE-X1s
SR6604 SR6608 SR6604 SR6608 SR6604 SR6608 SR6604 SR6608
FIP-240
2 4 2 4 2 4 1 3
MIM
8 16 8 16 8 16 4 12
HIM
4 (8
half-heig
ht HIMs)
8 (16
half-heig
ht HIMs)
4 (8
half-heig
ht HIMs)
8 (16
half-heigh
t HIMs)
4 (8
half-heigh
t HIMs)
8 (16
half-heigh
t HIMs)
2 (4
half-heigh
t HIMs)
6 (12
half-heigh
t HIMs)
Service aggregation platform modules
A service aggregation platform (SAP) module provides network ports for receiving packets from the
network and sending packets to the network. This section describes the SAPs available for the H3C
SR6604 and SR6608 routers.
SAP-48GBE
The SAP-48GBE has 48 high-performance RJ-45 ports that can be both routed and switched. One
two-color LED is available for each port to indicate their activity and link status. The module also has a
RUN LED to indicate the module operating status.