Teac MX-2424 v1.15 User Manual
Page 90

ViewNet MX
ViewNet MX Version 1.1/1.5 Owners Manual
90
2 Channel in
When selected, the dedicated stereo digital inputs are routed to a group of eight tracks, with the left input
routed to the odd-numbered tracks (1,3,5,7), and the right input routed to the even-numbered tracks
(2,4,6,8). In addition to this menu, it will be necessary to choose which stereo digital I/O to use in menu
462, and to select 2CH as the Sample Reference in Menu 002.
Analog 1-8
When selected, input to tracks are taken from inputs 1-8 of the analog I/O module (IF-AN24) if installed.
This allows the MX-2424 to be used with analog 8-buss mixers.
Digital 1-8
When selected, input to tracks are taken from inputs 1-8 of a digital I/O module (IF-AE24, IF-AD24, IF-
TD24). This allows the MX-2424 to be used with digital 8-buss mixers.
Digital In rate converter
This setting allows real time sample rate conversion in conjunction with the optional
IF-AE24 AES/EBU digital I/O. The default is set to off.
2 Channel in rate converter
This setting enables the sample rate converters on the stereo AES/EBU and SPDIF interfaces. This
setting defaults to off.
2 Channel input source
This setting allows you to choose between the stereo AES/EBU and SPDIF interfaces as inputs.
2 Channel output select
This setting selects the pair of coincident tracks from the MX 2424 as the output source for the
AES/EBU and S/PIF stereo outputs.
2 Channel output encoding
This setting allows the chosen stereo digital outputs to send out either AES/EBU (professional) or SPDIF
(consumer) protocol. The default setting is professional.