beautypg.com

Talk pause= 20, Redial pause= 00, Sense level= 11 – Skutch Electronics BA-1000 V3.12 Technical Reference Manual User Manual

Page 33: Remote operation, Access unit remotely, Remote record a play only message, Start dialing file 9

background image

Version 3.12

Page 33

!

Talk Pause= 20

This option tells the system how many seconds

of silence it needs in order to stop recording and
continue with the outgoing message. For this
option, 1 = .1 seconds. The display will look as
follows:

Talk Pause= 20
00 to 99 #=Next

Enter from

01

01

01

01 to 99

99

99

99 then press then

release

#

#

#

# to go to the next option. You can press

then release

~

~

~

~ to return to the

Total Calls

screen.

!

Redial Pause= 00

This option tells the system the minimum

number of minutes that must expire, from the start of
the current dialing loop, before the system can start
the next redial loop. The display will look as
follows:

Redial Pause= 00
00 to 60 #=Next

Enter from

00

00

00

00 to 60

60

60

60 then press then

release

#

#

#

# to go to the next option. You can press

then release

~

~

~

~ to return to the

Total Calls

screen.

!

Sense Level= 11

This option lets you manually set the sensitivity

level for the system’s answer detect. CAUTION:
This value should NOT be adjusted unless instructed
to by a Skutch Service Technician.

Sense Level= 11
01 to 20 #=Next

Enter the level from

01

01

01

01 to 20

20

20

20 then

press then release

#

#

#

# to go to return to the Total

Calls screen. You can press then release
~

~

~

~ to return to the

Total Calls

screen.

Remote

Operation

This version supports a simple remote

programming feature that lets you, optionally, record
a new “Play Only” message and make the system
call all of the phone numbers in file 9. This feature
is only intended for calling a customer base of
numbers, previously entered into file 9.

!

Access Unit Remotely

The remote access will only be possible when

the system is at MENU, in Power Down state or at
End Of Session in dialing mode.

Call the unit.
The unit gives you a 2 tone beep after the 10

th

to 11

th

ring.

Enter the

Remote Access Code

, then

#; the

default is 0506, as follows:
0 5 0 6 #

The unit gives you a 3 tone beep, indicating

menu.

!

Remote Record a Play

Only Message

At the remote menu (after the 3 tone beep),

enter:
8

When Long, Low tone stops, dictate your

message.

When finished, enter:

*

It will play it back and return to the remote

menu.

!

Start Dialing File 9

At the remote menu (after the 3 tone beep),

enter:
3

The unit gives you two, 3 tone beeps, then 3

single beeps and hangs up. The system will restore