Chapter 7: LCD Setup Menu

User Guide: LD5000

18 970.484.6510

www.rletech.com

CHAPTER 7: LCD SETUP MENU


The Setup Menu allows authorized users to adjust the LD5000’s settings. Each menu option displays a
different adjustable parameter. Press Esc to exit the Setup Menu and return to the Main Menu.

7-1

TRIPPOINTS

The TripPoints option allows users to modify the detection and contamination trip points for the LD5000.
These trip points help the system avoid false alarm readings. Throughout this menu, the user can also set
the leak alarm and contamination alarm delays (20 to 3600 seconds). Press Esc to exit the TripPoint Menu
and return to the Setup Menu.

7-2

CLOCK

OPTION

The Clock option allows users to modify the LD5000’s date and time settings. Press Esc to exit the Set
Clock function and return to the Setup Menu.

7-3

RE-ALARM

The Re-Alarm option allows users to determine the number of minutes between annunciations of the same
alarm. Enter 000 to disable this feature. Factory default is “0” (disabled). Press Esc to exit and return to
the Setup Menu.

Set Clock:
01/10/01 10:51
^ ^

Modify Contamination
TripPoint: 050 uA

Modify Detection
TripPoint: 150 uA

Modify Contamination
Alarm Delay:
120

Seconds

+/- then (Enter)

Modify Leak Alarm
Delay:
20

Seconds

+/- then (Enter)

** TripPoint Menu **
Leak LeakDelay
->Contam ContDelay

** TripPoint Menu **
->Leak LeakDelay
Contam ContDelay

** Setup Menu **
->TripPoints Clock
Re-Alarm Ft/M
Calibrate FcDft