Menu structure / Menu navigation / Terminal configuration
Level 1
Level 0
T-external
T-collector
Automatic 1
Mo
Home
08:30
30 Mar 09
15.3 °C
36.2 °C
Main menu
End
01
Terminal
Controller
Level 2
Terminal
End
01
Language English
BUS code BM Off
Terminal On
Terminal
End
04
Change code
Communic Controller On
E81-P Min 80
Terminal
End
07
E81-V Min ----
By pressing the function
key of the respective
line you can reach
change mode directly.
The situation shown
here in the example is
if you want to change
the language of the text
display. Saving takes
place after selection by
pressing the function
key on the line where it
says OK.
Designation
Description
Language
The following languages are available:
German, English, French, Dutch, Spanish, Italian
BUS code BM
• OFF: Only operating function on the heat pump.
No additional controller active. No digital remote control present.
• 00-15: Number of the heating circuit for which the digital remote control should be activated.
Address 01 must always be used for heating circuit 1 (direct heating circuit) and
Address 02 must always be used for heating circuit 2 (mixing circuit).
Terminal
Is always set to ON and cannot be changed. The controller/display unit is designated as Terminal (BM-
T Control module -Terminal) Only a BM-T can be connected to the controller, which is why no address
assignment is possible here.
Change code
The 4-digit code for changes of parameters in the Specialist level is shown here and can be changed.
Note: Changing the code means that the Technical Support from REMKO is not longer available.
Communic Controller Is always set to ON and cannot be changed.
E81-P Min
E81-V Min
Current operating mode
(Operating mode)
Available modes:
- Stand by
- Cooling
- Automatic 1
- Automatic 2
- Summer
- Heating
- Reduction
- Service
(For a description of the
operating modes, see page 16)