Remko heat pump manager – REMKO Multi-talent User Manual
Page 18
REMKO HEAT PUMP MANAGER
Heating circuit 1/2-continued
Designation
Value range
Factory setting
Description
T-supply const T
10°C-110°C
35.0°C
This function is only active once the HK function was
programmed to T-feed const in the specialist menu.
Setting the desired supply temperature with which the selected
heating circuit is operated during the heating period.
T-supply const N
10°C-110°C
10.0°C
This function is only active once the HK function was
programmed to T-feed const in the specialist menu.
Setting the desired supply temperature with which the
selected heating circuit is operated during the reduction
period.
Room impact
Off
00-20
Off
This function is only activated with the analogue remote
control (FBR-2).
The WE temperature is increased in the amount of the value
set here if the desired room temperature (T-room target) is
undercut by 1K (room sensor impact).
Heating curve ad-
aptation
On/Off
Off
Automatic regulation of the heating curve
(Heating curve adaptation).
Start-up requirements:
• Outdoor temperature < 8°C
• Operating mode is automatic 1/2
• Duration of the reduction phase at least 6 hours
The current room temperature is measured at the beginning
of the reduction period. This temperature is applied in
the following 4 hours as the target value for the room
regulation. The heating curve is calculated from the values
captured in this time period by the regulator for the supply
and outdoor temperatures.
The setting remains on until the adaptation has been
completed successfully and was not interrupted (e.g. by
a demand for hot water from an external heating circuit).
The controller's water heating and the warm up
optimisation are blocked during the adaptation.
Warm up opt
Off
T-room
T-external
Off
Automatic bringing forward of the heating period start
(warm up optimisation).
Depending on the weather (T-outside) or the current room
temperature (T-room, only possible with the attachment
of the analogue room device (FBR-2)), heating is started
up early enough so that at the beginning of the set
heating period, the temperature in the living area (see time
programme
heating circuit 1/2 prog 1/2) just reaches
the set room target temperature (T-room target).The warm
up optimisation is only carried out if the reduction time for
the heating circuit is at least 6 hours.
Level 4 - USER - Description of parameters and settings - continued
18