REMKO Multi-talent User Manual
Page 19
Designation
Value range
Factory setting
Description
Max warm up-time
00:00-03:00
02:00
Setting the time by which the heating start should as
a maximum be brought forward (maximum bringing forward).
Reduction opt
00:00-03:00
00:00
Automatic optimisation of the switch-on time of the heat
pump at the end of the set heating period.
The heat pump is no longer started if it is not already in
operation for the duration of time set here prior to the end
of the heating period (only for the last heating period) (see
time programme
heating circuit 1/2 prog 1/2). (This
prevents short-term warming up of the heat pump at the
end of the heating period).
PC enable
0000-9999
0000
Code number to allow access to the heating circuit data via PC.
Heating circuit 1/2-continued
Level 4 - USER - Description of parameters and settings - continued
19