REMKO HEAT PUMP MANAGER
Factory setting
Designation
Day
Time
Is activated in the operating mode
Heating circuit 1
prog 1
Mo.-Fr.
Mo.-Su.
Sa.+Su.
06:00-22:00
06:00-22:00
07:00-23:00
Automatic 1
Heating circuit 1
prog 2
Mo.-Fr.
Mo.-Su.
Sa.+Su.
06:00-08:00, 16:00-22:00
06:00-08:00, 16:00-22:00
07:00-23:00
Automatic 2
Heating circuit 2
prog 1
Mo.-Fr.
Mo.-Su.
Sa.+Su.
06:00-22:00
06:00-22:00
07:00-23:00
Automatic 1
Heating circuit 2
prog 2
Mo.-Fr.
Mo.-Su.
Sa.+Su.
06:00-08:00, 16:00-22:00
06:00-08:00, 16:00-22:00
07:00-23:00
Automatic 2
Hot water
Mo.-Fr.
Mo.-Su.
Sa.+Su.
05:00-21:00
05:00-21:00
06:00-22:00
in all modes except for Stand by
Circulation pro-
gram
Mo.-Fr.
Mo.-Su.
Sa.+Su.
05:00-21:00
05:00-21:00
06:00-22:00
in all modes except for Stand by
WE 1-4 enable
Mo.-Fr.
Mo.-Su.
Sa.+Su.
00:00-24:00
00:00-24:00
00:00-24:00
The heating appliances can only be put into
operation in the enabled times set here.
(A demand for heat from a user or tank must
also exist for a heating appliance to operate)
WE1 = heat pump
WE2 = not used
WE3 = Electric heater or boiler
WE4 = not used .
S-Kick enable
Mo.-Su.
07:00-22:00
Enable time for the solar kick functions
(see specialist
solar MF).
PU night charging
Mo.-Su.
00:00-05:00
The second heating appliances are blocked
for the duration of the enable time set here.
In this time period, the buffer tank is only
warmed by the heat pump to the set tem-
perature (see specialist
heat pump
Min T-PU WE).
PU night charging should not be enabled in
the heating and hot water time periods.
All time programmes can be set here.
Level 4 - TIME PROGRAMME - Description of parameters and settings