beautypg.com

REMKO Multi-talent User Manual

Page 23

background image

Designation

Description

Software number

Display of the software number with index.

Manual cascade operation

Only for cascades; the operating mode Service must be activated.
Setting the heating appliance's output (For a switching, multi-level WE, the second level can be
switched on with a performance target of > 50%).
Inputs are automatically reset when the Service function is ended.

Burner running-time

Display of the heating appliance running time for all levels.

Burner starts

Display of the heating appliance starts for all levels.

STB test

Safety temperature limiter test with display of the temperature for the WE. (Start with the F-key)

Customer service

Input of the date for the annual maintenance reminder (at Year = "00" no reminder) or input of the
running time for the system after which a maintenance reminder should generate
(for running time < "50" no reminder).

Reset user

Respective areas can be reset to the factory setting using the reset function (factory setting = "01").

Reset specialist

Reset time programme

Communication BM 1

Remote control HC 1 at the BUS.

Communication BM 2

Remote control HC 2 at the BUS.

Communication KM

Communication with expansion module (for additional heating circuits).

Additional entries

Relay test

Select the desired relay using the rotary knob at the service level (01-11)
The selected relay is switched on for 1 minute and all other relays are switched off.

Please note that the input of the code number is required for this function.
The relay test breaks off automatically after 5 minutes if no further operation takes place.

Relays Output

Description

00

Normal operation => relays switch in accordance with the regulating function

01

A1

Circulation pump heating circuit 1 (direct heating circuit) on

02

A2

Circulation pump heating circuit 2 (mixer circuit) on

03

A3

Switch valve/charge pump DHW

04

A4

Mixer heating circuit 2 open

05

A5

Mixer heating circuit 2 closed

06

A6

Enable heat pump on (charge pump run parallel)

07

A7

For EMF/EMT 100/150;CMF/CMT 120/160: Enable cooling

For CMF 80/140: 2. Heating appliance on

For CMF 90/150 and CMT100/150 circulation pump cooling on

08

A8

Enable 2nd heating appliance (multi-function 1-output)

09

A9

Charge pump inside unit (multi-function 2-output)

10

A10

For CMF 80/90: Condenser pump

For CMF/CMT 120/160, EMF/EMT 100/150, CMF 90/150, CMT 100/150:

Switch valve cooling (multi-function 3-output)

12

A12

Circulation pump or solar pump or charge pump UP-solid fuel boiler

(Multi-function 4-output)

Level 4 - SERVICE - Description of parameters and settings - continued

23