Configuration
Designation
Value range
Factory setting
Description
Terminal address
On/Off
On
The BM-T is a terminal (input device). If there are
more than one terminal at the BUS, each must be
given a different terminal address.
BUS code 1
00-15
01
Heating circuit 1 (direct heating circuit is set to
the 1st address in the BUS system (heating circuit
number); the same number may not be assigned
more than once.
BUS code 2
00-15
02
Heating circuits 2 are numbered in sequence begin-
ning with "02".
eBUS supplay
On/Off
Off
Activation of eBUS supply for connected devices.
Changing of the set specialist values is not possible until the code number has been input because setting the
values incorrectly can lead to malfunctions and damage to the system.