REMKO Multi-talent User Manual
Page 13
Level 4 - DISPLAY - Description of parameters and settings
DISPLAY
Display of system values
Values cannot be changed in the display section.
There is a display only if the respective sensor is connected or the value exists in the system. If the setting does
not exist, it is either hidden or dashes (----) are shown in the display.
Factory settings can vary depending on the system.
Plant
Designation
Description
T-external
Current outdoor temperature [sensor 09] (smoothed value).
T-collector
Current collector temperature [sensor 08] and (collector) target temperature Display following pressing
of the respective function key.
The target corresponds with the highest temperature demanded in the load circuits (incl. water heating).
T-WE
Current temperature of all connected heating appliances [sensor 08].
WE status
Heating appliance's status (on / off).
T-return total
Current temperature [sensor 17].
T-tank 3
Current temperature of the tank 3/buffer tank bottom [sensor 01]. No assignment by REMKO
Modgrad
Current target modulation depths for all active WE and required modulation depth.
Error
Error number (00 = no errors).
Hot water
End
01
T-WW
T-WW U
WW demand
WW pump
WW enable
Circulation pump
Heating circuit 2
End
01
T-room
T-supply
Heating circuit enable
Heating circuit pump
B-warm up-time
Heating circuit 1
End
01
T-room
T-supply
Heating circuit enable
Heating circuit pump
B-warm up-time
Solar / MF
End
01
MF 1
MF 2
T-MF 3
MF 3
MF 4
T-solar 1
T-WW
T-WW U
Solar pump 1
Load Sp WW
01
Plant
End
T-external
T-collector
T-WE
WE status
T-return total
T-tank 3
Modgrad
Error
See page 13
See page 14
See page 14
See page 14
See page 14
Hot water
Designation
Description
T-WW
Current hot water temperature [sensor 06] and after press the corresponding button hot water target
temperature
T-WW U
Current temperature of the buffer tank bottom [sensor 12]
WW demand
Status of heat demand hot water (on/off).
WW pump
Status of the hot water charge pump (on/off) / or actuated 3-way switch valve.
WW enable
Enable water heating (on/off).
Circulation pump
Circulation pump status (on/off).
13