E 51
Notice that annual maintenance is needed
E 54
Message: “Heat pump fault”.The flow monitor has tripped. A flow problem has occurred.
Possible causes are air in the system, a clogged dirt trap or a defect of the charging pump in
the indoor module. If the red indicator lamp illuminates, there is a problem in the outdoor
module which can only be remedied through customer service.
E 55
“Power company shut-off” message. Information that the power company has begun an
off-period. The heating pump is switched off. The second heating appliance is switched on
as necessary. The electrical heating must be locked on-site using a relay switch.
E 69
Failure or short in supply sensor HK2 (mixing circuit). Sensor F5
E 70
Failure or short inlet pipe WP Multi-purpose sensor 1 Sensor F11
E 71
Failure or short in lower buffer sensor Sensor F12
E 75
Failure or short, external sensor Sensor F9
E 76
Failure or short, domestic water sensor Sensor F6
E 78
Failure or short, collector sensor Sensor F8
E 80
Failure or short, room sensor heating circuit 1. No assignment by REMKO
E 81
EEPROM error. The valid value has been replaced by the default value. Check parameter
values!
E 90
Address 0 and 1 on bus. Bus codes 0 and 1 may not be used simultaneously.
E 91
Bus code assigned. The set bus code is already being used by another device.
E 135
Failure or short, lower WW buffer sensor, multifunction sensor 2. No assignment by REMKO
E 137
Failure or short in collector sensor 1, multifunction sensor 4. Sensor F14
E 140
Failure or short in return line (cooling-mode control sensor) Sensor F17
E 200 - E 207
Communication heating appliance 1 to WE 7
E 220 - E 253
Communication BM 0 to BM 15
E 240
Communication Manager
E 241
Communication (individual) heating appliances
E 242
Communication mixer
E 243
Communication Solar
Heat pump manager error
codes
The error codes listed in the table
can be called up in the display
of the heat pump manager. See
Controller ---> Displays --->
System ---> Errors. If an error with
a corresponding code is present,
an error scan can be performed by
pressing the assigned function key.
After a short period of time the 10
most recent faults, including the
date and time, are listed with the
exception of error codes 54 and
55. They are treated as recurring
messages and are not listed in the
error scan.
67