Remko heat pump manager – REMKO Multi-talent User Manual
Page 56
REMKO HEAT PUMP MANAGER
Designation
Value range
Programming
Output/level
00 – 9950 kW
WE 1 level 1 = 50
WE 3 level 1 = 1
continue with key next to "End"
MF 1 function
0 0 - 3 6
0 0
T - MF 1 target
- 2 0 °C - 9 0 °C
( ---- )
MF 1 Hyst
2 K - 1 0 K
( ---- )
MF 1 Hyst Off
2 K - 1 0 K
( ---- )
MF 2 function
0 0 - 3 6
18
T - MF 2 target
- 2 0 °C - 9 0 °C
( ---- )
MF 2 Hyst
2 K - 1 0 K
( ---- )
MF 2 Hyst Off
2 K - 1 0 K
( ---- )
MF 3 function
0 0 - 3 6
3 4
T - MF 3 target
- 2 0 °C - 9 0 °C
( ---- )
MF 3 Hyst
2 K - 1 0 K
( ---- )
MF 3 Hyst Off
2 K - 1 0 K
( ---- )
MF 4 function
0 0 - 3 6
2 3
T - MF 4 target
- 2 0 °C - 9 0 °C
( ---- )
MF 4 Hyst
2 K - 1 0 K
5,0K
MF 4 Hyst Off
2 K - 1 0 K
2,0K
F15 function
0 0 - 0 8
0 7
E 1 function
0 0 - 0 3
0 2
E 2 function
0 0 - 0 3
0 3
Sensor
1k/5k sensors
5k sensors
Designation
Value range
Programming
BUS code BM
Off, 00-15
Off
Language
D/GB/F/NL/E/I
D (German)
Terminal address
On / Off
On
Time
0-24
Set time
Date
Year, month, day
Set date
BUS code 1
00-15
01
BUS code 2
00-15
02
System selection
---/01-12
07
Regulator type
00-06
06
WE 1 type
00-09
07
WE BUS
00-05
05
Gradient
On / Off
Off
WE 2 type
00-22
08
WE 2 tank
00-03
00
WE 3 type
00-09
01
WE 4 type
00-09
00
Buffer type
00-02
00
Cooling mode
Off/On
On
HC1 function
Standard,T-feed
const, swimming
pool, WW,
return
Standard
HC2 function
see HC1
Standard
B
A
AB
F9
F14
A
B
AB
F6
F8
F12
A
B
AB
l/h
Tmax
V
V
F17
F11
II
0
I
3)
A9
A3
A6
A12
A3
A10
A8
M
2)
1)
F5
A2
A4/A5
A10
4)
Hydraulic diagram for the heat pump assembly 11
Functions: Heating or cooling, hot water and solar
monoenergetic operating mode
“System selection 7”
Multi-function
Storage tank
MPS 1000
Outdoor unit
Indoor unit
CMF 120/160
EMF/EMT 100/150
Heating circuit
Taps
CW inlet
Fresh water station
Cooling circuit
Cooling water
Storage tank
KPS 300
Notes:
1) Heating circuit circulation pump(s) not included in REMKO's scope of delivery. We recommend the use of high-efficiency circulation pumps.
2) We recommend, because of possible high temperatures - caused by the solar plant, to always connect the heating circuit via a 3-way mixer.
3) If a circulation pump is installed, it must be controlled separately.
4) The cooling must be activated via heating circuit 1 by setting T-supply cooling to the desired cooling target supply temperature.
Sample hydraulic diagram for system selection 7
56