REMKO HEAT PUMP MANAGER
Heating circuit 1/2
Designation
Description
T-supply
Current supply temperature [sensors 05/08] and supply target temperature following pressing of the
respective function key.
Heating circuit enable Heating circuit in heating mode (on/off).
Heating circuit pump Heating circuit pump status (on/off).
B-warm up-time
Last required warm up-time with active warm up optimisation.
Solar / MF
Designation
Description
MF 1
Status of the relay MF 1 (on/off) outlet A8 - 2nd heating appliance.
MF 2
Status of the relay MF 2 (on/off) outlet A9 - charge pump indoor unit.
T-MF 3
Current temperature of the MF 3 sensor [sensor 13] - not used by REMKO.
MF 3
Status of the relay MF 3 (on/off) outlet A10 - 3-way switch valve cooling / MP cooling
MF 4
Status of the relay MF 4 (on/off) outlet A12 - solar-circulation pump.
T-solar 1
Current collector temperature [sensor 14].
T-WW
Current hot water temperature and hot water target temperature [sensor 6].
T-WW U
Current temperature of the buffer tank bottom [sensor 12] (sensor collector system).
Solar pump 1
Status of the collector pump (on/off).
Load Sp WW
Status of the tank charge pump 1 (on/off) not used by REMKO.
Level 4 - DISPLAY - Description of parameters and settings - continued
14