OVERVIEW
12
VCC-X Controller Technical Guide
Parts and Descriptions
PART NO.
PART DESCRIPTION
ILLUSTRATION
PAGE NO.
OE508
Prism 2 Front-End Computer Software
Prism 2 provides standard, easy to understand status screens for each
type of VCC-X equipment installed. Prism software has provisions for cus-
tom screens which allow fl oor plans, equipment photos, or user-defi ned
summary screens to be implemented to meet their own individual needs.
All controlling setpoints, trend logs, and alarm conditions are accessed in
the Prism environment. Prism can be confi gured for direct on-site installa-
tion, remote modem connection, or TCP/IP Internet connection to several
installations.
OE365-
15-EBA-A
E-BUS Adapter Board
The E-BUS Adapter Board is used for connecting the EBTRON
®
, Green-
Trol
TM
, or Paragon Airfl ow Measurement Digital Transmitter to the VCC-X
Control System. The E-BUS Adapter Board connects to the VCC-X Con-
troller with an EBC E-BUS cable. Cable supplied separately.
Page 45
MS000248
E-BUS Adapter Hub
The E-BUS Adapter Hub is used for connecting E-BUS devices and
Controllers together with EBC E-BUS cables of varying lengths. Includes:
E-BUS Adapter Hub.
Page 45
HZ-EBC-248
E-BUS Adapter Hub with 1.5 Foot EBC E-BUS Cable
The E-BUS Adapter Hub is used for connecting E-BUS devices and
Controllers together with EBC E-BUS cables of varying lengths. Includes:
E-BUS Adapter Hub and 1.5 foot EBC E-BUS cable.
Page 45
OE437-03
Communication Surge Protector Kit
Used to isolate power surges to the communications wiring caused by
lightning strikes for communications wiring loops that are routed outdoors
or between buildings. One kit is required at each point where the commu-
nications wiring leaves or enters a building.
Includes: Communication Bus Surge Protector, Base Module, and Mount-
ing/Wiring Instructions.
N/A
OE310-21-LP
Lighting Controller
Adds lighting control capability to the VCC-X Control System. Lighting
Controller provides up to (7) independent time schedules. Provisions for
photocell or light sensor light level control are also provided. Lighting
Controller only provides Pilot Duty Relay Outputs. An external Lighting
Contactor must be provided by others. If a Light Sensor OE259 is to be
used with the Lighting Controller, it must also be ordered from WattMaster.
Includes: Lighting Controller with Backplate.
N/A
OE259
Light Sensor
Ambient Light Sensor
(Use with Lighting Controller for light sensing.)
24VDC power, 1m Ohm to 1.5k Ohm output signal. Supplied with weather-
proof handy box for outdoor or indoor mounting. Light Sensor threads into
conduit fi tting. Includes: Light Sensor and weatherproof handy box.
N/A
OE377-26-
00058
MODGAS-X Controller
The
MODGAS-X Controller modulates up to (2) gas valves to maintain
a desired Discharge Air Temperature. It also controls the speed of the
induced draft fan to maintain proper combustion in the heat exchanger.
The MODGAS-X Controller connects to the VCC-X Controller via an EBC
E-BUS cable. Available only from AAON.
Page 53.