Serial-to-LAN Connection Installation
Page 46
MDE-4520C Enhanced Communications Installation Manual · February 2008
Figure 31: Test PC to Gasboy System Connections through the LAN Adapter
Gasboy System
C04532
Serial to
LAN Adapter
Test PC
CAT-5 Cross
Cable
Q13850-C06
SHM
C05618
Gasboy
Termination Box
Gasboy
D-Type
Connector
C05769
OR
OR
Ethernet Port
7
At the Test PC, open a command prompt session. At the command prompt, type the command
ping followed by the IP address for the Gasboy system adapter (for example, ping
192.168.1.101) and then press ENTER. Verify there are a series of Reply from messages and
no errors. If errors are returned, ensure the adapter is powered and check the cross cable
connection. It may be necessary to change the Test PC IP address so that the first three sets of
numbers are the same as the adapter IP address (for example, 192.168.1). If errors are still
being returned, try another adapter.
Figure 32: Ping Session
- 216S (18 pages)
- Atlas Fuel Systems Site Prep Manual (42 pages)
- Atlas Technician Programming Quick Ref (2 pages)
- ATC M05819K00X Kits (28 pages)
- Atlas Fuel Systems Owner Manual (80 pages)
- Gilbarco Global Pumping Unit Operation Manual (42 pages)
- 26 (7 pages)
- Atlas Valve Replacement Kits (10 pages)
- Atlas Fuel Systems Installation Manual (100 pages)
- 9120K (8 pages)
- 9820K (6 pages)
- Atlas Single Std. Inlet Centering Kit (8 pages)
- 8800 Atlas (1 page)
- 9120K Series Service Manual (40 pages)
- 9800A Atlas (6 pages)
- 9800 Atlas (14 pages)
- 9800 Atlas (20 pages)
- M08400 (6 pages)
- 9100 Series (8 pages)
- 9820K Series Installation (62 pages)
- 9853K (8 pages)
- 9216KTW (36 pages)
- Recommended Spare Atlas (14 pages)
- DEF Atlas (28 pages)
- 9820K Series (12 pages)
- 9800Q (1 page)
- Q Series (3 pages)
- 8753E (2 pages)
- 9152AXTW2 (1 page)
- 8800E (2 pages)
- 8800E (1 page)
- 9820Q Series (1 page)
- Atlas Start-up (230 pages)
- 9820A (1 page)
- 2600A (3 pages)
- 2600A (12 pages)
- 2600A (2 pages)
- 9800Q Front Load Vapor (2 pages)
- 215A (1 page)
- 9800A (4 pages)
- 216A (31 pages)
- 215A (2 pages)
- 9800Q Vapor (2 pages)
- Lamp Kit (2 pages)
- 9120Q Pulser (1 page)