beautypg.com

Gasboy Enhanced Communications User Manual

Page 15

background image

MDE-4520C Enhanced Communications Installation Manual · February 2008

Page 15

Site Installation Review and Considerations

Figure 5: TopKAT Dispenser Mount

DC COMMUNICATION CONDUIT

AC POWER - SYSTEMS AND PUMPS/DISPENSERS

TopKAT

Antenna Mast

18” Minimum

Conduit (supplied by installer)

20 Feet Maximum

Modem Enclosure Assembly

Figure 6: Gasboy System (Series 1000, Islander)

PUMP/DISPENSER AC POWER

DC COMMUNICATION CONDUIT

AC POWER - SYSTEMS AND PUMPS/DISPENSERS

DC RS-485/Pulser

18” Minimum

18” Min

Gasboy System

Antenna Mast

Modem Enclosure Assembly

20 Feet Max

Conduit (supplied
by installer)