Gasboy Enhanced Communications User Manual
Page 36

Serial-to-LAN Connection Installation
Page 36
MDE-4520C Enhanced Communications Installation Manual · February 2008
4
To make changes, enter the number assigned to the parameters to be changed and follow the
prompts until all information has been entered. All parameters not listed in the table on
, and
should be left at their default values.
• When a parameter prompt is displayed, the current value is shown in parentheses at the
end of the prompt. To change the value, type the new value and press ENTER.
• If you do not want to change the existing value of a parameter, just press ENTER without
entering any data.
5
Once you have set the parameters you wish to change, enter “9” and press ENTER to save the
changes.
Note: Changes are not saved until you save them (that is, entering 9 and then pressing
ENTER).
If your network has a DHCP server that has assigned an IP address to the adapter, or if an IP
address has been previously assigned, you can access the setup menu (
or
on
) by using Telnet.
To access via Telnet, open a Telnet connection to port 9999.
Consult with your Network Administrator for the device IP address or identification assigned
to the adapter for the Telnet connection.