Serial-to-LAN Connection Installation
Page 42
MDE-4520C Enhanced Communications Installation Manual · February 2008
Verifying the Connectivity to the Serial-to-LAN Adapter
Verifying the Connectivity from the Telnet Program
Connectivity can be verified using a program such as Telnet (
). When starting the
session, the program being used usually requires the IP address and port number. Enter the IP 
address and port number set in the adapter connected to the Gasboy system. 
If you are using Serial Tunneling in a Direct Connect mode, the adapter connected to the serial 
port of the PC must be turned off before you can verify connectivity to the Gasboy system 
adapter using this method.
Figure 28: Telnet Screen
Verifying the Connectivity from Terminal Emulation Program
If you are using Serial Tunneling option, you can verify connectivity between the Gasboy 
system and PC adapters using a terminal emulation program such as Hyper Terminal.
When you use a terminal emulation program such as Hyper Terminal (adapter in Direct 
Connect or Modem mode), you will need to open the COM port that the adapter is connected 
to on the PC. You will also need to match the communication parameters set on the adapter 
(baud rate, number of bits, parity, stop bits). All Gasboy systems use the same communication 
parameters: 8 bits, no parity, 1 stop bit. The baud rate should be set to match the port on the 
Gasboy system. 
If you are using the Direct Connect mode, start the terminal emulation session and you should 
be able to communicate to the Gasboy system just as if it were directly connected to the COM 
port.