beautypg.com

At the gasboy system end, For cable details, refer to, At the – Gasboy Enhanced Communications User Manual

Page 14: Gasboy system end

background image

Site Installation Review and Considerations

Page 14

MDE-4520C Enhanced Communications Installation Manual · February 2008

At the Gasboy System End

Note: The fueling position assembly must be mounted no lower than 18 inches above the

ground and no closer than 18 inches to any fuel dispenser.

Antenna Mast or Tower

• The height of the mast or tower will be determined by the line of sight requirement

between this antenna and the PC wireless antenna.

• You are allowed to use a 10-foot mast, or a 10-foot tower and 10-foot mast (11 feet to 18

feet total height), or a 20-foot 1 or 2 section tower and 10-foot mast (21 feet to 28 feet total
height) without the use of guy wires.

• If a tower base section is used, the manufacturers’ requirements for the installation of that

tower must be followed for the height of the tower installed.
Note: A tower and mast section is preferred as it encloses the wireless modem inside the

tower and protects it from being damaged.

Figure 4: Modem Inside the Tower

Modem Inside
the Tower

Gasboy System
(TopKAT)

Distance to the Modem Enclosure

For Gasboy systems other than a pedestal mount TopKAT unit, the modem enclosure must not
be more than 20 feet (6.1 meters) away. All other wire and conduit requirements specified in
the system installation manual must be followed.
Note: Do not use collar and conduit supplied with the kit.