beautypg.com

Settings for the adapter connected to a pc – Gasboy Enhanced Communications User Manual

Page 39

background image

MDE-4520C Enhanced Communications Installation Manual · February 2008

Page 39

Serial-to-LAN Connection Installation

Settings for the Adapter Connected to the Gasboy System

Once you have access to the setup menu (

Figure 26

on

page 37

or

Figure 27

on

page 38

), the

following parameters must be set to the value listed for the adapter connected to the Gasboy
system. All other values should be left at their default values. To view/edit the parameters
below, enter “1” at the “Your choice?” prompt and press ENTER.

Parameter
(

Figure 26

on

page 37

)

Value

Definition

Baud rate

Set to match baud rate of the port to which the
adapter is connected

9600 is the default value

I/F Mode

4C

RS-232C, 8 bits, no parity, 1 stop bit

Flow

05

XON/OFF pass characters to host

Port

(see note below)

Range: 1 - 65535

Connect Mode

C0

Accept unconditional, no active startup

Disconn Mode

C0

Disconnect with DTR drop, Telnet mode

Flush Mode

44

Input buffer - clear at disconnect
Output buffer - clear at disconnect

Note: Every TCP connection is defined by a destination IP address and port number. For example, a Telnet

application commonly uses port number 23. A port number is similar to an extension on a private branch
exchange (PBX) telephone system. A range of port numbers are available: 1 - 65535. Port numbers 0, 7, and
9999 are reserved and must not be assigned to the adapter.

After the parameters have been changed, you can press ENTER at the “Your choice?” prompt
to display the current values. Remember to save the settings once they are set correctly (see

below).

Consult with your Network Administrator for changes to the IP address, gateway address,
subnet mask, or security changes. To change IP address, gateway address, subnet mask
parameters, enter “0” at the “Your choice?” prompt and then press ENTER. To change
security parameters, enter “6” at the “Your choice?” prompt and then press ENTER.
Remember to save the settings once they are set correctly.

Once the parameters are set correctly, save the settings and exit setup by entering “9” at the
prompt and then press ENTER.

Settings for the Adapter Connected to a PC

If you are using the Serial Tunneling option, you will also have a Serial-to-LAN adapter
connected to a serial port on a PC. As described in

Serial-to-LAN Configuration Options

on

page 28

, there are two modes:

Direct connection - virtual hard-wired serial connection
Modem emulation - allows PC to “dial” the Gasboy system via a LAN connection