Serial-to-LAN Connection Installation
Figure 25: Lantronix Channel 1 Connection Settings Screen – Model UDS1100
Configuring the Adapter from the Serial Port Login – UDS10 or UDS1100
To configure the Adapter from the serial port login, proceed as follows:
1
Connect a terminal or PC running a Terminal Emulation program to the serial port of the
adapter. The default serial port settings are 9600 baud, 8 bits, no parity, 1 stop bit.
2
To enter Setup (Configuration) mode, cycle power (power off and back on) on the adapter.
After power-up, the self-test begins and the red diagnostic LED starts blinking. You will have
one second to enter three lowercase “x” characters.
Note: The easiest way to enter the Setup mode is to hold down the “x” key at the terminal (or
Emulation Program) while powering up the adapter.
3
When “Press Enter for Setup Mode” appears, press ENTER.
The display in the Setup menu is as shown in the following figures.
•