DT-4500-A Series Downconverters
Revision 1
Front Panel Operation
MN-DT4500A
5–7
CONFIG: Remote Control ETHERNET ADDRESS
IP Address/Range:
192.168.001.002/24
To edit the IP Address and Range for the Ethernet M&C port for this unit: First, use the
◄ ►
arrow keys to select the digit to edit, and then use the
▲ ▼ arrow keys to edit the value of that
digit. Press ENTER when done.
CONFIG: Remote Control ETHERNET GATEWAY
Ethernet IP Gateway:
192.168.001.002
To edit the IP Gateway Address for the Ethernet M&C port for this unit: First, use the
◄ ►
arrow keys to select the digit to edit, and then use the
▲ ▼ arrow keys to edit the value of that
digit. Press ENTER when done.
CONFIG: Remote Control ETHERNET SNMP
COMMUNITIES TRAPS
Use the
◄ ►
arrow keys to select the parameter to configure: COMMUNITIES or TRAPS.
CONFIG: Remote Control ETHERNET SNMP COMMUNITIES
SNMP Communities:
READ WRITE TRAP
Use the ◄ ►arrow keys to select READ, WRITE, or TRAP, and then press ENTER.
CONFIG: Remote Control ETHERNET SNMP
COMMUNITIES READ
Read Community:
public
You may view or edit the SNMP Read Community string. To edit, first use the
◄
►
arrow keys to select the character to edit, and then use the
▲ ▼ arrow keys
to edit that character. Press ENTER when done.
CONFIG: Remote Control ETHERNET SNMP
COMMUNITIES WRITE
Write Community:
private