A.7.2 configuration commands, A.7.2.1 frequency, A.7.2.2 attenuator – Comtech EF Data DT-4500-A Series User Manual
Page 125: A.7.2.3 cold start

DT-4500-A Series Downconverters
Revision 1
Appendix A
MN-DT4500A
A–15
A.7.2 Configuration Commands
A.7.2.1 Frequency
The default RF frequency of the unit is equal to its minimum operating frequency (RF
Low
).
Command
Details
Set Frequency:
Confirmation: >DEV/FRE_xxxxx.xxx'cr''lf'] Retrieve Frequency: Confirmation: >DEV/FRE_xxxxx.xxx'cr''lf'] Note: For example, xxxx.xxx = 14000.000 to 14500.000 MHZ in 125 KHz steps for Model UT - 4514-A A.7.2.2 Attenuator The default attenuation value is 10.00 dB. Command Details Set Attenuator: Confirmation: >DEV/ATT_yy.yy'cr'lf'] Retrieve Attenuator: Confirmation: >DEV/ATT_ yy.yy'cr''lf'] Note: yy.yy = 00.00 to 25.00 dB in 0.25 dB steps. A.7.2.3 Cold Start The cold start function, if enabled, mutes the output signal for a predetermined time following Power-Up to ensure a stable reference oscillator (15 minutes). The default is OFF. This command is disabled in redundant systems (i.e., COMMAND NOT AVAILABLE). Command Details Set Cold Start: Confirmation: >DEV/CLD_xxx'cr''lf'] Retrieve Status: Confirmation: >DEV/CLD_xxx'cr''lf']