A.7.1.23 Application Identification
The Application Identification (AID) command allows a free form message to be created. It is
intended to identify either the satellite, transponder, beam, destination or other aspects of the
application that may be significant to operations.
The message length corresponds to capability of the LCD and is 48 characters in total. The
second line begins at character 25, therefore, blanks must be used after line 1 information in
order to space to line 2. A carriage return ends the command. Trailing blanks will be generated
to fill the LCD field. The AID display will alternate with the Equipment type display by use of the
clear function key on the front panel. The default is "AID MESSAGE".
Command
Details
Application ID:
Confirmation: >DEV/AID_'cr' xxxxxxxxxxxxxxxxxxxxxxxx'cr' xxxxxxxxxxxxxxxxxxxxxxxx'cr''lf'] Retrieve ID: Confirmation: >DEV/AID_'cr' xxxxxxxxxxxxxxxxxxxxxxxx'cr' xxxxxxxxxxxxxxxxxxxxxxxx'cr''lf'] Note: xxxxxxx ... xxxxx = Your message, maximum 48 characters. A.7.1.24 Force Reboot The FRB command allows the unit to be forced to reboot after five seconds. This value is write- only. Command Details Force Reboot: Confirmation: >DEV/FRB_YES'cr''lf']