DT-4500-A Series Downconverters
Revision 1
Ethernet-based Remote Product Management
MN-DT4500A
6–16
Click [Change Configuration] to save. Otherwise, click [Reset] to revert to the previously
assigned parameters.
Mute
Use the drop-down list to select Configuration Mute Mode as On or Off, and then click [Change].
Carrier Mute Mode
Use the drop-down list to select Carrier Mute Mode as On or Off, and then click [Change].
Cold Start Mute
Use the drop-down list to select the Cold Start Mute function as On or Off, and then click
[Change].
Fault Recovery
Use the drop-down list to select the Fault Recovery function as MANUAL or AUTOMATIC, and
then click [Change].
Channel Slope Adjustment
Enter a slope value (0.0 to 1.0) in 0.1 steps. Click [Change] when done.
Serial
•
Interface Type: Use the drop-down list to select the operating serial mode as RS-485 or
RS-232.
•
Remote Address: Enter a valid remote control address from 0001 to 9999.
•
Baud Rate: Use the drop-down list to select the operating baud rate as 100, 2400, 4800,
9600, 19200 or 38400 baud.
•
Data bits – Parity – Stop Bits: Use the drop-down list to select the asynchronous character
format as:
o 8-N-1 (8 data bits, no parity, 1 stop bit)
o 7-O-2 (7 data bits, odd parity, 2 stop bits
o 7-E-2 (7 data bits, even parity, 2 stop bits).
Click [Change Serial Configuration] to save.