A.7.1.10 baud rate, A.7.1.11 lcd contrast, A.7.1.12 lcd brightness – Comtech EF Data DT-4500-A Series User Manual
Page 120: A.7.1.13 screen saver mode

DT-4500-A Series Downconverters
Revision 1
Appendix A
MN-DT4500A
A–10
A.7.1.10 Baud Rate
The default baud rate is 9600.
Command
Details
Set Baud Rate:
Confirmation: >DEV/SBR_xxxx'cr''lf'] Retrieve Baud Rate: Confirmation: >DEV/SBR_xxxx'cr''lf'] A.7.1.11 LCD Contrast This legacy command does not control any hardware, but its syntax is still supported to allow backwards compatibility with existing monitor and control applications. The default LCD contrast is 15. Command Details Set Contrast: Confirmation: >DEV/CON_xx'cr''lf'] Retrieve Contrast: Confirmation: >DEV/CON_xx'cr''lf'] A.7.1.12 LCD Brightness This legacy command does not control any hardware, but its syntax is still supported to allow backwards compatibility with existing monitor and control applications. The default LCD brightness is 15. Command Details Set Brightness Confirmation: >DEV/LCD_xx'cr''lf'] Retrieve Brightness: Confirmation: >DEV/LCD_xx'cr''lf'] A.7.1.13 Screen Saver Mode This legacy command does not control any hardware, but its syntax is still supported to allow backwards compatibility with existing monitor and control applications. The default screen saver mode is 0. Command Details Set SSM: Where: x=0 to 5 Confirmation: >DEV/SSM_x'cr''lf'] Retrieve SSM: Confirmation: >DEV/SSM_x'cr''lf']