EXT AGC: MIN PWR

10.0 VOLTS


Sets the AGC voltage for a receive signal level of -25.0 dBm. The voltage range is 0.0 to
10.0V, in 0.5V steps.

Upon entry, the current external AGC voltage level is displayed. Press [

↑] or [↓] to

increment or decrement the AGC voltage level in 0.5V steps. Press [ENTER] to execute the
change.

Note: For any receive signal level between -25.0 and -60.0 dBm, the software will
interpolate the required AGC voltage.

3.4.5.4.17 SYSTEM:MASTER

RESET

MASTER RESET

HARD/SOFT



CAUTION

Initiating a hard reset will reset the modem and place the
default configuration settings in ROM. Initiating a soft reset
will reset the modem hardware, but saves the current
configuration settings

.

Select [ENTER] once to access HARD or SOFT.
Press [

←] or [→] to make the selection. Press [ENTER].

Press [

→] five times to move the cursor to YES. Select YES and press [ENTER] again.


Note: The following parameters do not revert to default settings after a hard reset:

• Address
• Parity
• Baud Rate
• Remote Type
• Ext AGC: Min Pwr
• Ext AGC: Max Pwr
• Display Contrast