Comtech EF Data SNM-1002 User Manual
Page 167
SNM-1002 LinkSync
Modem
Revision 2
Remote Control Operation
MN/SNM1002.OM
A–41
Modem
Options/
Misc.
Information
Command:
Response:
s,HGH_PWR'cr'
s,HGH_STAB'cr'
s,ASLT'cr'
s,VIT'cr'
s,SEQ'cr'
s,SR'cr'
s,LRV'cr'
s,FRV'cr'
s,CARD_1_PCB'cr'
s,CARD_2_PCB'cr'
s,CARD_3_PCB'cr'
s,8PSK_2/3'cr'
s,TX_ONLY'cr'
s,RX_ONLY'cr''lf']
(0 or +) High Power
(0 or +) High Stability
(- or +) Asymmetrical Loop Timing
(- or +) Viterbi Encoder/Decoder
(- or +) Sequential Encoder/Decoder
(- or +) Single Code/Data Rate
(- or +) Low Rate Variable
(- or +) Full Rate Variable
(x or +) Card #1 Installed
(x or +) Card #2 Installed
(x or +) Card #3 Installed
(- or +) 8PSK 2/3 Code Rate
(0 or +) TX Only Operation
(0 or +) RX Only Operation
Notes:
1.
s = 0 (Not Installed, Not Upgradable).
2.
- (Not Installed, FAST Upgradable).
3. +
(Installed).
4.
X (Not Installed, Field Upgradable).
Serial
Number
Command:
Response:
MODEM_xxxxxxxxx'cr'
CARD_1_xxxxxxxxx'cr'
(Note
1)
CARD_2_xxxxxxxxx'cr'
(Note
2)
CARD_3_xxxxxxxxx'cr''lf']
(Note
3)
Where: xxxxxxxxx = Serial number 000000000 to
999999999.
Notes:
1.
Data is only returned if Card #1 is installed.
2.
Data is only returned if Card #2 is installed.
3.
Data is only returned if Card #3 is installed.
Built In Self
Test
Command:
Response:
Status:
Response:
>add/BIST_xxxx'cr''lf']
for (RUN):
>add/BIST_xxxx'cr'
ST_xxx'cr''lf']
Where: xxxx = OFF (self test disabled), RUN (run self
test now), AUTO (run self test on power up/software
restart).
Self Test (OK/FLT)
Note: Allow 35 Seconds for response to RUN the Self
Test.