Comtech EF Data SNM-1002 User Manual

Page 140

background image

SNM-1002 LinkSync

 Modem

Revision 2

Remote Control Operation

MN/SNM1002.OM

A–14

MTDP_4_yyy'cr' (Note

10)

MTMD_4_yyyyy'cr' (Note

10)

MTAF_4_yyy'cr' (Note

10)

MTDR_5_yyyyyy'cr' (Note

10)

MTIT_5_yyyyy'cr' (Note 10)
MTCP_5_yyy'cr' (Note

10)

MTDP_5_yyy'cr' (Note

10)

MTMD_5_yyyyy'cr' (Note

10)

MTAF_5_yyy'cr' (Note

10)

MTDR_6_yyyyyy'cr' (Note

10)

MTIT_6_yyyyy'cr' (Note 10)
MTCP_6_yyy'cr' (Note

10)

MTDP_6_yyy'cr' (Note

10)

MTMD_6_yyyyy'cr' (Note

10)

MTAF_6_yyy'cr' (Note

10)

MTDR_7_yyyyyy'cr' (Note

10)

MTIT_7_yyyyy'cr' (Note 10)
MTCP_7_yyy'cr' (Note

10)

MTDP_7_yyy'cr' (Note

10)

MTMD_7_yyyyy'cr' (Note

10)

MTAF_7_yyy'cr' (Note

10)

MTDR_8_yyyyyy'cr' (Note

10)

MTIT_8_yyyyy'cr' (Note 10)
MTCP_8_yyy'cr' (Note

10)

MTDP_8_yyy'cr' (Note

10)

MTMD_8_yyyyy'cr' (Note

10)

MTAF_8_yyy'cr' (Note

10)

TRSI_xx'cr'
T310_xxx'cr'
RF_xxx'cr''lf']

Mux Tributary #4 Interface Type
Mux Tributary #4 Clock Phase
Mux Tributary #4 Data Phase
Mux Tributary #4 Mode
Mux Tributary #4 Async Mode
Mux Tributary #5 Data Rate & Enable
Mux Tributary #5 Interface Type
Mux Tributary #5 Clock Phase
Mux Tributary #5 Data Phase
Mux Tributary #5 Mode
Mux Tributary #5 Async Mode
Mux Tributary #6 Data Rate & Enable
Mux Tributary #6 Interface Type
Mux Tributary #6 Clock Phase
Mux Tributary #6 Data Phase
Mux Tributary #6 Mode
Mux Tributary #6 Async Mode
Mux Tributary #7 Data Rate & Enable
Mux Tributary #7 Interface Type
Mux Tributary #7 Clock Phase
Mux Tributary #7 Data Phase
Mux Tributary #7 Mode
Mux Tributary #7 Async Mode
Mux Tributary #8 Data Rate & Enable
Mux Tributary #8 Interface Type
Mux Tributary #8 Clock Phase
Mux Tributary #8 Data Phase
Mux Tributary #8 Mode
Mux Tributary #8 Async Mode
TX Reed-Solomon Interleave Value
TX 8PSK 2/3 IESS-310 Operation
RF Output (ON/OFF)

This command is used by the Adaptive
Boradband M:N protection switch to collect
information that is necessary to configure back-
up modems. Because this command (content
and/or order) can be changed at any time by
Adaptive Boradband, it is advisable that other
commands ('MCS_' and 'ICS_', or 'BCS_') be
used for M&C systems.

Notes:

1

Data is only returned if FLEX MUX PCB (Card Slot
#1) is installed.

2.

Data not returned if Channel #1 is disabled.

3.

Data not returned if Channel #3 is disabled or set
for AUPC.

4.

Data not returned if Channel #4 is disabled or set
for AUPC.

5

Data is only returned for TX ASYNC
Overhead( or Flex Mux AUPC).

6. Data not returned if Local AUPC is enabled

& TX ASYNC overhead.

7. Data is only returned for TX D&I Overhead.

Data is only returned for TX IDR Overhead.

Data is only returned for TX ASYNC
Overhead (or Flex Mux D&I).

10. Data is only returned if MUX PCB (Card Slot

#1) is installed.