Comtech EF Data SNM-1002 User Manual
Page 140
SNM-1002 LinkSync
Modem
Revision 2
Remote Control Operation
MN/SNM1002.OM
A–14
MTDP_4_yyy'cr' (Note
10)
MTMD_4_yyyyy'cr' (Note
10)
MTAF_4_yyy'cr' (Note
10)
MTDR_5_yyyyyy'cr' (Note
10)
MTIT_5_yyyyy'cr' (Note 10)
MTCP_5_yyy'cr' (Note
10)
MTDP_5_yyy'cr' (Note
10)
MTMD_5_yyyyy'cr' (Note
10)
MTAF_5_yyy'cr' (Note
10)
MTDR_6_yyyyyy'cr' (Note
10)
MTIT_6_yyyyy'cr' (Note 10)
MTCP_6_yyy'cr' (Note
10)
MTDP_6_yyy'cr' (Note
10)
MTMD_6_yyyyy'cr' (Note
10)
MTAF_6_yyy'cr' (Note
10)
MTDR_7_yyyyyy'cr' (Note
10)
MTIT_7_yyyyy'cr' (Note 10)
MTCP_7_yyy'cr' (Note
10)
MTDP_7_yyy'cr' (Note
10)
MTMD_7_yyyyy'cr' (Note
10)
MTAF_7_yyy'cr' (Note
10)
MTDR_8_yyyyyy'cr' (Note
10)
MTIT_8_yyyyy'cr' (Note 10)
MTCP_8_yyy'cr' (Note
10)
MTDP_8_yyy'cr' (Note
10)
MTMD_8_yyyyy'cr' (Note
10)
MTAF_8_yyy'cr' (Note
10)
TRSI_xx'cr'
T310_xxx'cr'
RF_xxx'cr''lf']
Mux Tributary #4 Interface Type
Mux Tributary #4 Clock Phase
Mux Tributary #4 Data Phase
Mux Tributary #4 Mode
Mux Tributary #4 Async Mode
Mux Tributary #5 Data Rate & Enable
Mux Tributary #5 Interface Type
Mux Tributary #5 Clock Phase
Mux Tributary #5 Data Phase
Mux Tributary #5 Mode
Mux Tributary #5 Async Mode
Mux Tributary #6 Data Rate & Enable
Mux Tributary #6 Interface Type
Mux Tributary #6 Clock Phase
Mux Tributary #6 Data Phase
Mux Tributary #6 Mode
Mux Tributary #6 Async Mode
Mux Tributary #7 Data Rate & Enable
Mux Tributary #7 Interface Type
Mux Tributary #7 Clock Phase
Mux Tributary #7 Data Phase
Mux Tributary #7 Mode
Mux Tributary #7 Async Mode
Mux Tributary #8 Data Rate & Enable
Mux Tributary #8 Interface Type
Mux Tributary #8 Clock Phase
Mux Tributary #8 Data Phase
Mux Tributary #8 Mode
Mux Tributary #8 Async Mode
TX Reed-Solomon Interleave Value
TX 8PSK 2/3 IESS-310 Operation
RF Output (ON/OFF)
This command is used by the Adaptive
Boradband M:N protection switch to collect
information that is necessary to configure back-
up modems. Because this command (content
and/or order) can be changed at any time by
Adaptive Boradband, it is advisable that other
commands ('MCS_' and 'ICS_', or 'BCS_') be
used for M&C systems.
Notes:
1
Data is only returned if FLEX MUX PCB (Card Slot
#1) is installed.
2.
Data not returned if Channel #1 is disabled.
3.
Data not returned if Channel #3 is disabled or set
for AUPC.
4.
Data not returned if Channel #4 is disabled or set
for AUPC.
5
Data is only returned for TX ASYNC
Overhead( or Flex Mux AUPC).
6. Data not returned if Local AUPC is enabled
& TX ASYNC overhead.
7. Data is only returned for TX D&I Overhead.
Data is only returned for TX IDR Overhead.
Data is only returned for TX ASYNC
Overhead (or Flex Mux D&I).
10. Data is only returned if MUX PCB (Card Slot
#1) is installed.