SNM-1002 LinkSync

 Modem

Revision 2

Maintenance

MN/SNM1002.OM

5–16

5.2.3.4

Receive Interface Faults

Fault/Alarm

Possible Problem and Action

BUFFER UNDERFLOW

Buffer underflow alarm.

Indicates the plesiochronous buffer has underflowed. Buffer underflow
is normally a momentary fault (there are clock problems if this alarm is
continuously present). This alarm is included in this section to be
consistent with the fault reporting system and to be correctly registered
in the stored fault memory. The time and date of the first 10 receive
buffer underflow faults are stored in battery-backed memory as an aid
to troubleshooting. The interval between stored overflow/underflow
events can be used to determine relative clock accuracies.

BUFFER OVERFLOW

Buffer overflow alarm.

Indicates the plesiochronous buffer has overflowed.

The problems and actions in the buffer underflow section apply to this
alarm.

RX DATA/AIS

Data or incoming AIS. The data monitored for RX data is coming from
the satellite.

When the AIS is selected for RX data fault in the Interface Utility
menu, the RX data/AIS is monitoring an alarm condition of all 1s from
the satellite. When data is selected for RX data fault in the Interface
Utility menu, the RX data/AIS is monitoring a fault condition of all 1s
or 0s. This is referred to as a data-stable condition (data is not
transitioning). The fault indicates trouble in receiving data from the
satellite. The modem passes this signal transparently, and can close a
FORM C contact. The indication is a monitor function only to help
isolate the source of trouble in a system.

FRAME BER

Not Applicable

BACKWARD ALARM

Not Applicable