Interface, A.3.3 interface – Comtech EF Data SNM-1002 User Manual
Page 134
SNM-1002 LinkSync
Modem
Revision 2
Remote Control Operation
MN/SNM1002.OM
A–8
A.3.3 Interface
Interface
Transmit
Overhead
Type
Command:
Response:
Status:
Response:
Where: xxxxx = NONE
Interface
Receive
Overhead
Type
Command:
Response:
Status:
Response:
Where: xxxxx = NONE
TX Driver
Type
Command:
Response:
Status:
Response:
Where: xxxxx = V35, RS422, or RS232.
RX Driver
Type
Command:
Response:
Status:
Response:
Where: xxxxx = V35, RS422, or RS232.
Transmit
Clock
Command:
Response:
Status:
Response:
Where: xxx = INT (internal SCT clock), EXT
(external TX terrestrial clock), REF (external clock-
reference frequency).
External
Clock-
Reference
Frequency
Command:
Response:
Status:
Response:
Where: nnnnn.n = 8.0 to 10000.0 (external clock
frequency in kHz).
Transmit
Clock
Phase
Command:
Response:
Status:
Response:
Where: xxxx = NRM (normal clock phasing), INV
(inverted clock phasing), AUTO (automatic clock
phasing).
Buffer
Clock
Command:
Response:
Status:
Response:
Where: xxx = INT (internal SCT clock), EXT
(external TX terrestrial clock), SAT (receive satellite
clock), REF (external clock-reference frequency),
INS (insert clock).
Receive
Clock
Phase
Command:
Response:
Status:
Response:
Where: xxx = NRM (normal clock phasing), INV
(inverted clock phasing).