Maintenance

MN/SNM1002.OM

5–2

5.1.1 Interface

Checkout

Use the following procedure and the test setup in Figure 5-1 to inspect the interface.

Figure 5-1. Fault Isolation Test Setup


1. Connect a BER test set to the appropriate modem data connector as shown in

Figure 5-1. Refer to Chapter 2 for external modem connections.


2. Set up the modem for baseband loopback operation by using the directions

provided in section A.3.3. The modem will run error free.

3. Change the modem from baseband loopback to interface loopback operation by

using the directions provided in section A.3.3. The modem will run error free.