beautypg.com

10 demodulator:reacquisition – Comtech EF Data SNM-1002 User Manual

Page 54

background image

SNM-1002 LinkSync

 Modem

Revision 2

Operation

MN/SNM1002.OM

3–14

SWEEP RANGE

60000 HZ


Displays the overall travel of the sweep width range during acquisition in the directed
sweep mode. The sweep width may be set from 0 to 70000 Hz. Default: 60000 Hz.

When set at 70000 Hz, the modem is in Normal acquisition mode. The smaller the range,
the faster the modem will lock, provided the receive carrier center frequency is within the
RX-IF frequency sweep range.

3.4.1.2.10 DEMODULATOR:REACQUISITION

REACQUISITION

0 SECONDS


Displays the sweep reacquisition mode time duration. This is the time that the modem
will remain in a narrow sweep after loss of acquisition. After this timer runs out, the
modem will return to the normal acquisition sweep. The reacquisition time is 0 to 999
seconds. Default: 0 seconds.