beautypg.com

Comtech EF Data SNM-1002 User Manual

Page 161

background image

SNM-1002 LinkSync

 Modem

Revision 2

Remote Control Operation

MN/SNM1002.OM

A–35

Bulk Consol.
Status
(continued)


Paramete
r
Number

Parameter Name
(Command Reference)


Description

(Note 9)


(Note 9)


(Note 9)


(Note 7)


(Note 10)


(Note 10)


(Note 10)


(Note 7)


(Note 11)


(Note 7)


(Note 7)



(Note 12)


(Note 12)


(Note 12)


(Note 7)


(Note 13)


(Note 13)

123


124


125


126


127


128


129


130


131


132


133



134


135


136


137


138


139

TX Flex Mux Channel #3 Data Rate
(ref. "TCDR_3" command).

TX Flex Mux Channel #3 Clock Phase
(ref. "TCCP_3" command).

TX Flex Mux Channel #3 Data Phase
(ref. "TCDP_3" command).

TX Flex Mux Channel #4 Enable
(ref. "TCEN_4" command).

TX Flex Mux Channel #4 Data Rate
(ref. "TCDR_4" command).

TX Flex Mux Channel #4 Clock Phase
(ref. "TCCP_4" command).

TX Flex Mux Channel #4 Data Phase
(ref. "TCDP_4" command).

RX Flex Mux Channel #1 Enable
(ref. "RCEN_1" command).

RX Flex Mux Channel #1 Data Rate
(ref. "RCDR_1" command).

RX Flex Mux Channel #2 Enable
(ref. "RCEN_2" command).

RX Flex Mux Channel #3 Enable
(ref. "RCEN_3" command).


RX Flex Mux Channel #3 Data Rate
(ref. "RCDR_3" command).

RX Flex Mux Channel #3 Clock Phase
(ref. "RCCP_3" command).

RX Flex Mux Channel #3 Data Phase
(ref. "RCDP_3" command).

RX Flex Mux Channel #4 Enable
(ref. "RCEN_4" command).

RX Flex Mux Channel #4 Data Rate
(ref. "RCDR_4" command).

RX Flex Mux Channel #4 Clock Phase
(ref. "RCCP_4" command).

RX Flex Mux Channel #4 Data Phase
(ref. "RCDP_4" command).

p123 = nnnn.n, where 'nnnn.n' is the data rate in Kbps.



p124 = n, where 'n' is '0' (Normal) or '1' (Invert).


p125 = n, where 'n' is '0' (Normal) or '1' (Invert).


p126 = n, where 'n' is '0' (Disabled), '1' (Sync
RS232), '2' (Async RS232), '3' (Async RS485), or
'4' (AUPC operation).

p127 = nnnn.n, where 'nnnn.n' is the data rate in Kbps.



p128 = n, where 'n' is '0' (Normal) or '1' (Invert).


p129 = n, where 'n' is '0' (Normal) or '1' (Invert).


p130 = n, where 'n' is '0' (Disabled), '1' (D&I), or '2'
(T1/E1 operation).

p131 = nnnn.n, where 'nnnn.n' is the data rate in
Kbps.


p132 = n, where 'n' is '0' (Disabled), '1' (Enabled).


p133 = n, where 'n' is '0' (Disabled), '1' (Sync
RS422), '2' (Async RS422), '3' (Sync RS232), '4'
(Async RS232), or '5' (AUPC operation).

p134 = nnnn.n, where 'nnnn.n' is the data rate in Kbps.


p135 = n, where 'n' is '0' (Normal) or '1' (Invert).



p136 = n, where 'n' is '0' (Normal) or '1' (Invert).


p137 = n, where 'n' is '0' (Disabled), '1' (Sync
RS232), '2' (Async RS232), '3' (Async RS485), or
'4' (AUPC operation).

p138 = nnnn.n, where 'nnnn.n' is the data rate in
Kbps.