SNM-1002 LinkSync

 Modem

Revision 2

Remote Control Operation

MN/SNM1002.OM

A–39


Character 'm': Interface receive side faults character
4.
Bit 6 = 1 always.
Bit 5 = RX Audio Channel 1 Clip.
Bit 4 = RX Audio Channel 2 Clip.
Bit 3 = reserved.
Bit 2 = reserved.
Bit 1 = reserved.
Bit 0 = reserved.

Character 'n': Common equipment fault status
character 1.
Bit 6 = 1 always.
Bit 5 = Monitor & Control Module.
Bit 4 = Interface Module.
Bit 3 through Bit 0 = Binary representation (0 to 10) of
the number of common equipment stored faults.

Character 'o': Common equipment fault status
character 2.
Bit 6 = 1 always.
Bit 5 = Battery/Clock.
Bit 4 = +5V power supply.
Bit 3 = reserved.
Bit 2 = +12V power supply.
Bit 1 = -12V power supply.
Bit 0 = reserved.

Character 'p': Interface backward alarm status
character 1.
Bit 6 = 1 always.
Bit 5 = TX Backward Alarm 1.
Bit 4 = TX Backward Alarm 2.
Bit 3 through Bit 0 = Binary representation (0 to 10) of
the number of backward alarm stored faults.

Character 'q': Interface backward alarm status
character 2.
Bit 6 = 1 always.
Bit 5 = TX Backward Alarm 3.
Bit 4 = TX Backward Alarm 4.
Bit 3 = RX Backward Alarm 1.
Bit 2 = RX Backward Alarm 2.
Bit 1 = RX Backward Alarm 3.
Bit 0 = RX Backward Alarm 4.

Character 'r': Interface Reed-Solomon Unavailable
Seconds
Bit 6 = 1 always.
Bit 5 = not used.
Bit 4 = not used.
Bit 3 through Bit 0 = Binary representation (0 to 10) of
the number of Reed-Solomon Unavailable Seconds
stored faults.